Gates offers the following hose options:
Look at the PSI and fluid temperature range to determine the best hose choice
Gates offers the following hose options:
Look at the PSI and fluid temperature range to determine the best hose choice
Best choice for fuel transfer
SAE 30R2
200 max working pressure
–40°F to +212°F (–40°C to +135°C) constant and +300°F (+100°C)
Permanent Couplings: G25
Gates offers the following fleet multi-use hose option that is recommended for fuel transfer
Best multi-fluid hose choice
SAE J1402, DOT FMVSS 106-74
(NOT APPROVED FOR BIO-DIESEL ABOVE B5)
1,250 max working pressure
–40°F to +300°F (–40°C to +149°C)
Phosphate esters to +212°F (+100°C)
Air to +250°F (+121°C) only
Field attachable/reusable couplings: C5 G34
Best choice for marine diesel applications
500 max working pressure
–4°F to +212°F (–20°C to +100°C)
Permanent couplings: G20
Field attachable/reusable couplings:G34
Brass/Carbon field attachable/reusable couplings: C5 G34
Gates offers the following lock-on hose option that is recommended for fuel transfer
300 max working pressure
–40°F to +250°F (–40°C to +121°C).
Air to +160°F (+71°C) only.
Fuel/Bio-diesel up t0 +125°F (+52°C)
Field attachable couplings: G36
Clamp over single bead: G37
Barbed with clamp: G38